IS16K - Vacuum Interlock Switch, D05914000
Variant
Explore the range of variants given below to compare the product
Short Description | Part Number | Pressure Measurement Max |
---|---|---|
D05914000 | 50000.00 | |
D05915000 | - |
Pressure Switch / Regulator
Portable gauging offers the opportunity to easily take spot measurement checks.
Thanks to it being mains power independent, the Edwards P3 handheld all-in-one measuring system is the essential device for:
Also available is the accessory pack, which not only gives you a case in which to transport the gauge, avoiding damage in transit, but also some dedicated PC software and mains cable to enable longer term measurement tracking and logging, past the standard onboard datalogging. This can enable pressure rise leak testing on large/underground systems where standard leak checking is not viable.
IS16K - Vacuum Interlock Switch
The IS16K vacuum interlock switch is designed to safeguard the operator by ensuring that electrical
circuits in the vacuum chamber do not remain energised when the system is let up to atmosphere.
Typical applications include interlocking of the HT cleaning or process circuits on thin film deposition and vacuum systems. The IS16K is high vacuum compatible and corrosion resistant, with all wetted parts made from stainless steel. A high current rating allows direct switching of loads without additional relays or external power supplies.
Features and Benefits
- Single non-adjustable set-point, cannot be tampered with.
- Positive break switch.
- Rapid contact separation, prevents arcing.
- Breaks circuit directly, no relays required.
- Corrosion resistant materials exposed to vacuum.
General Product Information
Connection Inlet Flange | DN 16 ISO-KF (NW16) |
Weight | 0.700 |
Leak Rate | 1.000 × 10⁻¹⁰ |
Dimension Length | 0.102 |
IP Rating | IP52 |
Dimension Height | 0.107 |
Dimension Width | 0.084 |
Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
Environmental Conditions
Temperature Ambient Operation Min | 268.15 |
Temperature Ambient Storage Min | 253.15 |
Temperature Ambient Storage Max | 343.15 |
Classification
Classification Principle of Measurement | Vacuum switch |
Performance Data
Pressure Measurement Max | 50000.00 |
Pressure Measurement Min | 25000.00 |
Material of Construction
Material Exposed to Vacuum | Stainless steel and Armco 17/7PH |
- P60061256 - Pump Module.pdf - Brazilian Portuguese - Instructions
- P60061251 - Pump Module.pdf - Czech - Instructions
- D1G1091100-A00_A_APG200_-_XM-DN16CF_CUSTOMR_REF.stp - English - Drawings
- D05914880 - Instructions.pdf - English - Instructions
- P60061200 - Pump Module.pdf - English - Instructions
- D05915880 - Instructions.pdf - English - Instructions
- 3601-0156-01-VS16K-IS16K-vacuum-switches.pdf - English - Technical Data
- P60061283 - Pump Module.pdf - French - Instructions
- D05915883 - Instructions.pdf - French - Instructions
- D05914882 - Instructions.pdf - German - Instructions
- P60061282 - Pump Module.pdf - German - Instructions
- D05915882 - Instructions.pdf - German - Instructions
- P60061284 - Pump Module.pdf - Italian - Instructions
- P60061246 - Pump Module.pdf - Simplified Chinese - Instructions
- D05914889 - Instructions.pdf - Swedish - Instructions